Brand Name : MITSUBISHI
Model Number : WDC-BI-V04
Certification : CO.CQ
Place of Origin : JAPAN
MOQ : 1
Price : inquiry
Payment Terms : T/T
Supply Ability : 10 pieces a day
Delivery Time : today
Packaging Details : new and original with factory sealed
Manufacture Year : 2020
Con 6DS1311-8AEtrol System : WDC-BI-V04
Application : Nuclear Power Plant
lead time : in stock
description : MITSUBISHI
Weight : 4lbs
MITSUBISHI WDC-BI-V04 Computer Communication Board Card
| Brand/Manufacturer | MITSUBISHI / JAPAN | 
| Part Number | WDC-BI-V04 | 
| Alternate Part Number | WDC-BI-V04 | 
| Description | Computer Communication Board Card | 
| Dimennsions | 15.6cm x 15.9cm x 3.4 cm | 
| Weight | 0.32kg | 
Product Details
Overcurrent protection
The overcurrent proctector shuts off the 5VDC and/or 24VDC circuit(s) and stops the system if the current exceeding the specified value flows in the circuit(s).
As this results in voltage drop, the power supply module LED turns OFF or is dimly lit.
When this device is activated, eliminate probable causes such as insufficient current capacity or short circuit, and then start the system. When the current has reached the normal value, the system will start from the first.
Overvoltage protection
The overvoltage protector shuts off the 5VDC circuit and stops the system if overvoltage of 5.5 to 6.5V is applied to the circuit.
The power supply module LED turns OFF. When restarting the system, switch the input power OFF, then back ON. The system is started up with an initial start.If the system is not booted and the LED remains off, this means that the power supply module has to be replaced.
Allowable period of momentary power failure
The allowable momentary power failure period of PLC CPUs varies depending on the power supply module used. In the system using the A63P, it is the time from when the primary side of
the stabilized power supply supplying 24VDC to the A63P turns OFF until the voltage (secondary side) has dropped from 24VDC to the specified value (15.6VDC) or less
Inrush current
If power is reapplied immediately after power OFF (within 5 seconds), an inrush current exceeding the specified value may flow (for 2ms or less). Therefore, before reapplying power, make sure that 5 seconds have elapsed after power off. When selecting a fuse or breaker for an external circuit, consider the above as well as meltdown and detection characteristics.
Moore News
POWER INDUSTRY
Thermal power industry with power industry capabilities:
 With the development of society, network technology, computer technology and PLC control technology are becoming more and more mature.
 All auxiliary control systems of thermal power plants can enter the whole plant auxiliary network control system to realize complete monitoring operation in the centralized control room. The level of automation has been greatly improved, and the efficiency of the whole plant has been improved.
 Process automation
 Human Machine Interface (HMI)
 Security system
 Servo drive motor
 If the required equipment is no longer produced by the original equipment manufacturer, It can be purchased through Moore Automationde's global industrial automation parts supplier to ensure production operations are in place.
More Products
| HONEYWELL | 51305508-200 | BENTLY NEVADA | 990-05-50-02-01 | 
| HONEYWELL | SPS5713 51199930-100 | BENTLY NEVADA | 991-06-50-01-01 | 
| HONEYWELL | 51202343-001 | BENTLY NEVADA | 3300/20 | 
| HONEYWELL | 51305896-200 | BENTLY NEVADA | 3300/30 | 
| HONEYWELL | CC-PDIS01 51405042-175 | BENTLY NEVADA | 136483-01 | 
| HONEYWELL | FC-TDOL-0724 | BENTLY NEVADA | 81544-01 | 
| GE | DS200UPSAG1AGD | SHNEIDER | 140CPU53414B | 
| GE | DS6800CCID1D1D | SHNEIDER | 140CRA21220 | 
| GE | DS200TCEAG1BTF | SHNEIDER | 140CRA93200 | 
| GE | DS200CPCAG1ABB | SHNEIDER | 140CRP93200 | 
| GE | DS200CTBAG1ADD | SHNEIDER | 140DAI55300 | 
Contact Us
miya@mvme.cn(Click)
Email: miya@mvme.cn
QQ: 2851195450
Tel: 86-18020776792
Skype: miyazheng52
|   | 
| MITSUBISHI WDC-BI-V04 Computer Communication Board Card Images | 
 Automobile SST-DN4-104-2 Automation DCS BRAD HARRISON WOODHEAD
                                                                                    
                        
                        
                        
                                                            Automobile SST-DN4-104-2 Automation DCS BRAD HARRISON WOODHEAD
                                                    
                        
                     IRDH265-4 BENDER A-ISOMETER Insulation Monitoring Device For IT AC Systems
                                                                                    
                        
                        
                        
                                                            IRDH265-4 BENDER A-ISOMETER Insulation Monitoring Device For IT AC Systems
                                                    
                        
                     ARISTA ARP-2610A Fanless Industrial HMI Panel Computer VIA 667 GHz
                                                                                    
                        
                        
                        
                                                            ARISTA ARP-2610A Fanless Industrial HMI Panel Computer VIA 667 GHz
                                                    
                        
                     5PP320.1043-39 5PP320.104339 B&R Power Panel PP320
                                                                                    
                        
                        
                        
                                                            5PP320.1043-39 5PP320.104339 B&R Power Panel PP320
                                                    
                        
                     Rexroth Bosch Indramat DKC10.3-012-3-MGP-01VRS DKC Series | Bosch DKC10.3-012-3
                                                                                    
                        
                        
                        
                                                            Rexroth Bosch Indramat DKC10.3-012-3-MGP-01VRS DKC Series | Bosch DKC10.3-012-3
                                                    
                        
                     FIREYE 95DSS2-1 95DSS2 1 95DSS21
                                                                                    
                        
                        
                        
                                                            FIREYE 95DSS2-1 95DSS2 1 95DSS21
                                                    
                        
                     31C011-503-4-00 826080X| EURODRIVE Frequenzumrichter Movitrac 31C011-503-4-00
                                                                                    
                        
                        
                        
                                                            31C011-503-4-00 826080X| EURODRIVE Frequenzumrichter Movitrac 31C011-503-4-00
                                                    
                        
                     31C015-503-4-00 8263337 | EURODRIVE Frequenzumrichter Movitrac 31C015-503-4-00
                                                                                    
                        
                        
                        
                                                            31C015-503-4-00 8263337 | EURODRIVE Frequenzumrichter Movitrac 31C015-503-4-00
                                                    
                        
                     X20DO2649 B&R X20 Digital Output Module
                                                                                    
                        
                        
                        
                                                            X20DO2649 B&R X20 Digital Output Module
                                                    
                        
                     HG-KN13BJ-S100 Mitsubishi Servo Drive
                                                                                    
                        
                        
                        
                                                            HG-KN13BJ-S100 Mitsubishi Servo Drive